Fire contact
The device has an Override emergency dry contact port (PANIC - GND) for fire emergency applications. When receiving the fire signal from the fire control center, the device will preferentially open the first loop as an emergency lighting circuit according to the signal.
Isolated input/output channels
Eight independent input/output channels form a one-to-one loop. The control of each channel loop can be configured through software. Each channel has a separate transient surge protection circuit and surge protection can reach 220V 25A. Each channel allows 16A resistive load current or 8A inductive load current, and supports control of electric curtain motors.
Centralized control
The module can be managed visually and centrally through SCHIDERON Intelligent Lighting Management System (LMS). The data of each channel in the device can be uploaded into the intelligent lighting management system for device data management and status analysis. Scene management is to preset the time to the device through the LMS, and then turn on the corresponding scene mode to reach all or part of the device loop.
DIN rail mounting
“Modular” equipment is flexibly installed and applied in the actual environment. The module is mounted on a standard 35mm DIN rail, providing convenient installation and maintenance for users.
S-Net bus modular design
The module is designed for the MCU pure hardware architecture and has local data processing and channel control. The overall power consumption of the module is low and the task processing is timely. The module communicates via the dedicated bus S-Net to ensure the stability and reliability of data transmission. Each device has a corresponding physical address. The DIP dialer can be used to set the device's address to ensure that each module can operate correctly and accurately receive and execute commands transmitted from S-Net.
Agreement type : S-Net Channel : 120-240VDC Placeholder : 10P DIN module space
Load type : Incandescent/Hydr.. Radiat : 10.6BTU/hr Consumption : 24VDC / 130mA
Terminals : PA66 Weight : 378.0g Temperature : 32°to 104°F
Storage TEM : 0℃~40℃ Material : ABS Humidity : 10%~90% RH
Installation : DIN rail mounting Size : 180*87*63(mm)
The 8-way 16A relay switch module (HRMS-RL-C08/16) is an 8-channel relay control device for 120VAC to 240VAC for incandescent, fluorescent, neon/cold-cathode, etc., 8 independent input/output isolations Channels and 8 emergency switch buttons allow manual switching of the circuit without bus devices and software. Each channel allows 16A resistive load current, or inductive load current of 8A, and supports electric curtain control and fan control. Intelligent lighting management system (LMS) can be used for independent loop control, pre-editing scene control and scene timing control. Device data can upload module local data to intelligent intelligent lighting management system (LMS) for device status management and statistical data analysis. The transmission and equipment control meets the latest industrial industry standards.
SDR-RL-C08/16- Simplified 2019 / 05 / 28 805.86K
SDR-RL-C08/16- Traditional 2019 / 05 / 28 211.65K
HRMS-RL-C08/16(Simplified Chinese) 2018 / 06 / 15 934.33K
HRMS-RL-C08/16(Traditional Chinese) 2018 / 07 / 19 934.33K